VM performance history

Collect VM CPU and memory history for sizing. Collection is opt-in, read-only, and stored apart from captures.

vsfleet capture perf --window 7d        # reads vCenter
vsfleet get perfcollections
vsfleet top vm                          # offline
vsfleet export rvtools --file e.xlsx    # adds the vsfleetPerformance sheet

vsfleet uses the finest vCenter statistics interval that covers the whole --window; --interval picks another. Samples are interval averages, typically 5 minutes to 2 hours, so a peak can understate a short spike.

Metric Unit Statistics level
cpu.usage percent 1
cpu.ready percent of time one vCPU waited 1
mem.active MiB 2
mem.consumed, mem.balloon MiB 1
mem.swapped MiB 2
mem.swapinRate KBps 1
mem.usage percent of configured memory 1

vCenter keeps level 1 by default, so mem.active and mem.swapped are usually missing. vsfleet then reads active memory from mem.usage and marks it with *. If neither is kept, raise the interval to level 2 in vCenter › Configure › General › Statistics and wait for history to build; vsfleet never changes this itself. Storage I/O is not collected.

Bounds and impact

--window, --max-samples, --max-vms, --max-requests and --max-runtime limit a collection. Reaching one marks it partial and lists the VMs not sampled. Each collection prints the requests it used and its runtime, and stores summaries rather than raw samples.

Unknown is never zero

Missing samples, such as powered-off time or expired history, never count as zero. A statistic is unavailable when its counter cannot be read, and insufficient-data with fewer than 12 samples or under half the window. P95 needs 50 samples.

Sizing signal

Signals describe the window; they are not resize instructions.

Signal Meaning
contention-observed CPU ready reached 5% per vCPU, or memory was ballooned or swapped. Outranks the others: a starved VM looks idle.
peaks-observed Usually under 30%, but a peak reached 60% or more
in-use Usage is not low
sustained-low Peaks stayed under 30% of CPU and memory for the whole window
cpu-only CPU is known; memory could not be read, so it is unknown, not low
insufficient-data Too few samples, including VMs powered off or not sampled
unavailable CPU usage could not be read

In reports

describe capture shows, for each context, the collection whose window covers the capture, or the nearest one and whether it falls before or after. VMs the collection did not sample are counted as not sampled. The vsfleetPerformance sheet has one row per VM per metric with the window, average, peak, P95, status and signal; a context without a collection gets one not collected row. capture prune removes old collections but keeps each context's newest.

Limits

On vCenter 8.0.3 at level 1, mem.usage matched active memory within 0.01 points. Another version that reports consumed memory there would make VMs look busier, never idler. The sustained-low, peaks-observed and in-use thresholds have not been checked against a real vCenter at level 2.